Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 160
1.
Magn Reson Imaging ; 2024 Apr 08.
Article En | MEDLINE | ID: mdl-38599503

BACKGROUND AND PURPOSE: Long acquisition times limit the feasibility of established non-contrast-enhanced MRA (non-CE-MRA) techniques. The purpose of this study was to evaluate a highly accelerated flow-independent sequence (Relaxation-Enhanced Angiography without Contrast and Triggering [REACT]) for imaging of the extracranial arteries in acute ischemic stroke (AIS). MATERIALS AND METHODS: Compressed SENSE (CS) accelerated (factor 7) 3D isotropic REACT (fixed scan time: 01:22 min, reconstructed voxel size 0.625 × 0.625 × 0.75 mm3) and CE-MRA (CS factor 6, scan time: 1:08 min, reconstructed voxel size 0.5 mm3) were acquired in 76 AIS patients (69.4 ±â€¯14.3 years, 33 females) at 3 Tesla. Two radiologists assessed scans for the presence of internal carotid artery (ICA) stenosis and stated their diagnostic confidence using a 5-point scale (5 = excellent). Vessel quality of cervical arteries as well as the impact of artifacts and image noise were scored on 5-point scales (5 = excellent/none). Apparent signal- and contrast-to-noise ratios (aSNR/aCNR) were measured for the common carotid artery (CCA) and ICA (C1-segment). RESULTS: REACT provided a sensitivity of 88.5% and specificity of 100% for clinically relevant (≥50%) ICA stenosis with substantial concordance to CE-MRA regarding stenosis grading (Cohen's kappa 0.778) and similar diagnostic confidence (REACT: mean 4.5 ±â€¯0.4 vs. CE-MRA: 4.5 ±â€¯0.6; P = 0.674). Presence of artifacts (3.6 ±â€¯0.5 vs. 3.5 ±â€¯0.7; P = 0.985) and vessel quality (all segments: 3.6 ±â€¯0.7 vs. 3.8 ±â€¯0.7; P = 0.004) were comparable between both techniques with REACT showing higher scores at the CCA (4.3 ±â€¯0.6 vs. 3.8 ±â€¯0.9; P < 0.001) and CE-MRA at V2- (3.3 ±â€¯0.5 vs. 3.9 ±â€¯0.8; P < 0.001) and V3-segments (3.3 ±â€¯0.5 vs. 4.0 ±â€¯0.8; P < 0.001). For all vessels, REACT showed a lower impact of image noise (3.8 ±â€¯0.6 vs. 3.6 ±â€¯0.7; P = 0.024) while yielding higher aSNR (52.5 ±â€¯15.1 vs. 37.9 ±â€¯12.5; P < 0.001) and aCNR (49.4 ±â€¯15.0 vs. 34.7 ±â€¯12.3; P < 0.001) for all vessels combined. CONCLUSIONS: In patients with acute ischemic stroke, highly accelerated REACT provides an accurate detection of ICA stenosis with vessel quality and scan time comparable to CE-MRA.

2.
Neuroradiol J ; : 19714009241240056, 2024 Mar 15.
Article En | MEDLINE | ID: mdl-38490750

OBJECTIVES: Glioses appear as hypodense lesions in non-contrast CT examinations of the head. Photon counting CT (PCCT) enables the calculation of virtual monoenergetic images (VMI). The aim of this study is to investigate in which VMI hypodense gliotic lesions can be delineated best. MATERIALS AND METHODS: 35 patients with an MRI-confirmed gliotic lesion and a non-contrast PCCT of the head were retrospectively included. All available VMI from 40 keV to 190 keV were calculated. In a quantitative analysis, conventional image quality parameters were calculated, in particular the contrast-to-noise ratio (CNR) of the hypodense lesion compared to the white matter. In a qualitative analysis, selected VMI were rated by experienced radiologists. RESULTS: The absolute maximum of CNR was 8.12 ± 5.64 in the VMI 134 keV, in post hoc testing, there were significant differences in comparison to VMI with keV ≤110 and keV ≥180 (corrected p < .05). In the qualitative analysis, there were only very slight differences in the rating of the VMI with 66 keV, 80 keV, 100 keV, and 134 keV with overall low agreement between the readers. CONCLUSIONS: The quantitative superiority of VMI 134 keV for the delineation of hypodense gliotic lesions did not translate into a superiority in the qualitative analysis. Therefore, it remains uncertain if the reconstruction of a high keV VMIs for the detection of hypodense gliotic lesions is useful in everyday clinical practice. However, more studies, are necessary to further assess this issue.

3.
Heliyon ; 10(6): e27636, 2024 Mar 30.
Article En | MEDLINE | ID: mdl-38509988

Rationale and objectives: Coronary computed tomography angiography (CCTA) is becoming increasingly important for the diagnostic workup of coronary artery disease, nevertheless, imaging of in-stent stenosis remains challenging. For the first time, spectral imaging in Ultra High Resolution (UHR) is now possible in clinically available photon counting CT. The aim of this work is to determine the optimal virtual monoenergetic image (VMI) for imaging in-stent stenoses in cardiac stents. Materials and methods: 6 stents with inserted hypodense stenoses were scanned in an established phantom in UHR mode. Images were reconstructed with 3 different kernels for spectral data (Qr56, Qr64, Qr72) with varying levels of sharpness. Based on region of interest (ROI) measurements image quality parameters including contrast-to-noise ratio (CNR) were analyzed for all available VMI (40 keV-190 keV). Finally, based on quantitative results and VMI used in clinical routine, a set of VMI was included in a qualitative reading. Results: CNR showed significant variations across different keV levels (p < 0.001). Due to reduced noise there was a focal maximum in the VMI around 65 keV. The peak values were observed for kernel Qr56 at 116 keV with 19.47 ± 8.67, for kernel Qr64 at 114 keV with 13.56 ± 6.58, and for kernel Qr72 at 106 keV with 12.19 ± 3.25. However, in the qualitative evaluation the VMI with lower keV (55 keV) performed best. Conclusions: Based on these experimental results, a photon counting CCTA in UHR with stents should be reconstructed with the Qr72 kernel for the assessment of in-stent stenoses, and a VMI 55 keV should be computed for the evaluation.

4.
Radiology ; 310(3): e230545, 2024 Mar.
Article En | MEDLINE | ID: mdl-38530174

Background Coronary artery calcium scoring (CACS) for coronary artery disease requires true noncontrast (TNC) CT alongside contrast-enhanced coronary CT angiography (CCTA). Photon-counting CT provides an algorithm (PureCalcium) for reconstructing virtual noncontrast images from CCTA specifically for CACS. Purpose To assess CACS differences based on PureCalcium images derived from contrast-enhanced photon-counting CCTA compared with TNC images and evaluate the impact of these differences on the clinically relevant classification of patients into plaque burden groups. Materials and Methods Photon-counting CCTA images acquired between August 2022 and May 2023 were retrospectively identified. Agatston scores were derived from both TNC and PureCalcium images and tested for differences with use of the Wilcoxon signed-rank test. The agreement was assessed with use of equivalence tests, Bland-Altman analysis, and intraclass correlation coefficient. Plaque burden groups were established based on Agatston scores, and agreement was evaluated using weighted Cohen kappa. The dose-length product was analyzed. Results Among 170 patients (mean age, 63 years ± 13 [SD]; 92 male), 111 had Agatston scores higher than 0. Median Agatston scores did not differ between TNC and PureCalcium images (4.8 [IQR, 0-84.4; range, 0.0-2151.8] vs 2.7 [IQR, 0-90.7; range, 0.0-2377.1]; P = .99), with strong correlation (intraclass correlation coefficient, 0.98 [95% CI: 0.97, 0.99]). The equivalence test was inconclusive, with a 95% CI of 0.90, 1.19. Bland-Altman analysis showed wide repeatability limits, indicating low agreement between the two scores. With use of the PureCalcium algorithm, 125 of 170 patients (74%) were correctly classified into plaque burden groups (excellent agreement, κ = 0.88). Patients without plaque burden were misclassified at higher than normal rates (P < .001). TNC image acquisition contributed a mean of 19.7% ± 8.8 of the radiation dose of the entire examination. Conclusion PureCalcium images show potential to replace TNC images for measuring Agatston scores, thereby reducing radiation dose in CCTA. There was strong correlation in calcium scores between TNC and PureCalcium, but limited agreement. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Sakuma in this issue.


Calcium , Computed Tomography Angiography , Humans , Male , Middle Aged , Coronary Vessels/diagnostic imaging , Retrospective Studies , Coronary Angiography , Tomography, X-Ray Computed
5.
Neuroradiology ; 66(5): 729-736, 2024 May.
Article En | MEDLINE | ID: mdl-38411902

PURPOSE: To determine the optimal virtual monoenergetic image (VMI) for detecting and assessing intracranial hemorrhage in unenhanced photon counting CT of the head based on the evaluation of quantitative and qualitative image quality parameters. METHODS: Sixty-three patients with acute intracranial hemorrhage and unenhanced CT of the head were retrospectively included. In these patients, 35 intraparenchymal, 39 intraventricular, 30 subarachnoidal, and 43 subdural hemorrhages were selected. VMIs were reconstructed using all available monoenergetic reconstruction levels (40-190 keV). Multiple regions of interest measurements were used for evaluation of the overall image quality, and signal, noise, signal-to-noise-ratio (SNR), and contrast-to-noise-ratio (CNR) of intracranial hemorrhage. Based on the results of the quantitative analysis, specific VMIs were rated by five radiologists on a 5-point Likert scale. RESULTS: Signal, noise, SNR, and CNR differed significantly between different VMIs (p < 0.001). Maximum CNR for intracranial hemorrhage was reached in VMI with keV levels > 120 keV (intraparenchymal 143 keV, intraventricular 164 keV, subarachnoidal 124 keV, and subdural hemorrhage 133 keV). In reading, no relevant superiority in the detection of hemorrhage could be demonstrated using VMIs above 66 keV. CONCLUSION: For the detection of hemorrhage in unenhanced CT of the head, the quantitative analysis of the present study on photon counting CT is generally consistent with the findings from dual-energy CT, suggesting keV levels just above 120 keV and higher depending on the location of the hemorrhage. However, on the basis of the qualitative analyses, no reliable statement can yet be made as to whether an additional VMI with higher keV is truly beneficial in everyday clinical practice.


Radiographic Image Interpretation, Computer-Assisted , Radiography, Dual-Energy Scanned Projection , Humans , Retrospective Studies , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Dual-Energy Scanned Projection/methods , Tomography, X-Ray Computed/methods , Intracranial Hemorrhages/diagnostic imaging , Signal-To-Noise Ratio
6.
Acad Radiol ; 2024 Feb 27.
Article En | MEDLINE | ID: mdl-38418345

RATIONALE AND OBJECTIVES: Common computed tomography (CT) investigation plays a limited role in characterizing and assessing the response of rectal cancer (RC) to neoadjuvant radiochemotherapy (NARC). Photon counting computed tomography (PCCT) improves the imaging quality and can provide multiparametric spectral image information including iodine concentration (IC). Our purpose was to analyze associations between IC and histopathology in RC and to evaluate the role of IC in response prediction to NARC. MATERIALS AND METHODS: Overall, 41 patients were included into the study, 14 women and 27 men, mean age, 65.5 years. PCCT in a portal venous phase of the abdomen was performed. In every case, a polygonal region of interest (ROI) was manually drawn on iodine maps. Normalized IC (NIC) was also calculated. Tumor stage, grade, lymphovascular invasion, circumferential resection margin, and tumor markers were analyzed. Tumor regression grade (absence/presence of tumor cells) after NARC was analyzed. NIC values in groups were compared to Mann-Whitney-U tests. Sensitivity, specificity, and area under the curve values were calculated. Intraclass correlation coefficient (ICC) was calculated. RESULTS: ICC was 0.93, 95%CI= (0.88; 0.96). Tumors with lymphovascular invasion showed higher NIC values in comparison to those without (p = 0.04). Tumors with response grade 2-4 showed higher pretreatment NIC values in comparison to lesions with response grade 0-1 (p = 0.01). A NIC value of 0.36 and higher can predict response grade 2-4 (sensitivity, 73.9%; specificity, 91.7%; area under the curve, 0.85). CONCLUSION: NIC values showed an excellent interreader agreement in RC. NIC can predict treatment response to NARC.

7.
Nutrition ; 120: 112327, 2024 Apr.
Article En | MEDLINE | ID: mdl-38341908

OBJECTIVES: Body composition on computed tomography can predict prognosis in patients with COVID-19. The reported data are based on small retrospective studies. The aim of the present study was to analyze the prognostic relevance of skeletal muscle parameter derived from chest computed tomography for prediction of 30-d mortality in patients with COVID-19 in a multicenter setting. METHODS: The clinical databases of three centers were screened for patients with COVID-19 between 2020 and 2022. Overall, 447 patients (142 female; 31.7%) were included into the study. The mean age at the time of computed tomography acquisition was 63.8 ± 14.7 y and median age was 65 y. Skeletal muscle area and skeletal muscle density were defined on level T12 of the chest. RESULTS: Overall, 118 patients (26.3%) died within the 30-d observation period. Of the patient sample, 255 patients (57.0%) were admitted to an intensive care unit and 122 patients needed mechanical ventilation (27.3%). The mean skeletal muscle area of all patients was 96.1 ± 27.2 cm² (range = 23.2-200.7 cm²). For skeletal muscle density, the mean was 24.3 ± 11.1 Hounsfield units (range = -5.6 to 55.8 Hounsfield units). In survivors, the mean skeletal muscle density was higher compared with the lethal cases (mean 25.8 ± 11.2 versus 20.1 ± 9.6; P < 0.0001). Presence of myosteatosis was independently associated with 30-d mortality: odds ratio = 2.72 (95% CI, 1.71-4.32); P = 0.0001. CONCLUSIONS: Myosteatosis is strongly associated with 30-d mortality in patients COVID-19. Patients with COVID-19 with myosteatosis should be considered a risk group.


COVID-19 , Sarcopenia , Aged , Female , Humans , Body Composition , COVID-19/complications , Muscle, Skeletal/diagnostic imaging , Muscle, Skeletal/pathology , Retrospective Studies , Risk Factors , Sarcopenia/complications , Sarcopenia/diagnostic imaging , Sarcopenia/pathology , Male , Middle Aged
8.
Eur J Radiol ; 173: 111374, 2024 Apr.
Article En | MEDLINE | ID: mdl-38422607

PURPOSE OF THE STUDY: The aim of the study was to identify differences in the tumor conspicuity of pancreatic adenocarcinomas in different monoenergetic or polyenergetic reconstructions and contrast phases in photon-counting CT (PCCT). MATERIAL AND METHODS: 34 patients were retrospectively enrolled in this study. Quantitative image analysis was performed with region of interest (ROI) measurements in different monoenergetic levels ranging from 40 up to 70 keV (5-point steps) and polyenergetic series. Tumor-parenchyma attenuation differences and contrast-to-noise-ratio (CNR) were calculated. A qualitative image analysis was accomplished by 4 radiologists using a 5-point Likert scale (1 = "not recognizable" up to 5 = "easy recognizable"). Differences between groups were evaluated for statistical significance using the Friedman test and in case of significant differences pair-wise post-hoc testing with Bonferroni correction was applied. RESULTS: Tumor-parenchyma attenuation difference was significantly different between the different image reconstructions for both arterial- and portal-venous-phase-images (p < 0.001). Tumor-parenchyma attenuation difference was significantly higher on arterial-phase-images at mono40keV compared to polyenergetic images (p < 0.001) and mono55keV images or higher (p < 0.001). For portal-venous-phase-images tumor-parenchyma attenuation difference was significantly higher on mono40keV images compared to polyenergetic images (p < 0.001) and mono50keV images (p = 0.03) or higher (p < 0.001). The same trend was seen for CNR. Tumor conspicuity was rated best on mono40keV images with 4.3 ± 0.9 for arterial-phase-images and 4.3 ± 1.1 for portal-venous-phase-images. In contrast, overall image quality was rated best on polyenergetic-images with 4.8 ± 0.5 for arterial-phase-images and 4.7 ± 0.6 for portal-venous-phase-images. CONCLUSION: Low keV virtual monoenergetic images significantly improve the tumor conspicuity of pancreatic adenocarcinomas in PCCT based on quantitative and qualitative results. On the other hand, readers prefer polyenergetic images for overall image quality.


Adenocarcinoma , Pancreatic Neoplasms , Radiography, Dual-Energy Scanned Projection , Humans , Retrospective Studies , Radiography, Dual-Energy Scanned Projection/methods , Tomography, X-Ray Computed/methods , Pancreatic Neoplasms/diagnostic imaging , Adenocarcinoma/diagnostic imaging , Signal-To-Noise Ratio , Radiographic Image Interpretation, Computer-Assisted
9.
Leuk Lymphoma ; : 1-8, 2024 Feb 21.
Article En | MEDLINE | ID: mdl-38384127

Studies regarding the influence of body composition parameters as predictors on overall survival (OS) in patients with multiple myeloma (MM) are scarce. OS and progression-free survival (PFS) were retrospectively assessed in 129 patients with MM undergoing autologous stem cell transplantation (ASCT) after a follow-up of 2 years. A computed tomography (CT) based semi-automated assessment of body composition was performed. No statistically significant differences were noted in 2-year OS, PFS, or post-transplant adverse events in the body composition groups of subcutaneous adipose tissue (SAT) (low vs. high-SAT), visceral adipose tissue (VAT) (low vs. high-VAT), visceral-to-subcutaneous fat ratio (VSR) (low vs. high VSR), and sarcopenia in terms of skeletal muscle index (SMI) (non-sarcopenic vs. sarcopenic). In conclusion, adipose and muscle tissue do not limit OS or affect the PFS in patients with MM undergoing ASCT.

10.
Acad Radiol ; 2024 Feb 16.
Article En | MEDLINE | ID: mdl-38368163

RATIONALE AND OBJECTIVES: Accurate and efficient estimation of patient height and weight is crucial to ensure patient safety and optimize the quality of magnetic resonance imaging (MRI) procedures. Several height and weight estimation methods have been proposed for use in adult patient management, but none is widely established. Estimation by the medical technologists for radiology (MTR) based on personal experience remains to be the most common method. This study aimed to compare a novel deep learning (DL)-based 3-dimensional (3D) camera estimation method to MTR staff in terms of estimation accuracy. METHODS: A retrospective study was conducted to compare the accuracy of height and weight estimation with a DL-based 3D camera algorithm to the accuracy of height and weight estimation by the MTR. Depth images of the patients were captured during the regular imaging workflow on a low field 0.55 T MRI scanner (MAGNETOM Free.Max, Siemens Healthineers, Erlangen, Germany) and then processed retrospectively. Depth images of a total of 161 patients were used to validate the accuracy of the height and weight estimation algorithm. The accuracy of each estimation method was evaluated by computing the proportions of the estimates within 5% and 15% of actual height (PH05, PH15) and within 10% and 20% of actual weight (PW10, PW20). An acceptable accuracy for height estimation was predetermined to be PH05 = 95% and PH15 = 99% and an acceptable accuracy for weight estimation was predetermined to be PW10 = 70% and PW20 = 95%. The bias in height and weight estimation was measured by the mean absolute percentage error (MAPE). RESULTS: The retrospective study included 161 adult patients. For 148/161 patients complying with inclusion criteria, DL-based 3D camera algorithm outperformed the MTR in estimating the patient's height and weight in term of accuracy (3D camera: PH05 =98.6%, PH15 =100%, PW10 =85.1%, PW20 =95.9%; MTR: PH05 =92.5%, PH15 =100%, PW10 =75.0%, PW20 =93.2%). MTR had a slightly higher bias in their estimates compared to the DL-based 3D camera algorithm (3D camera: MAPE height=1.8%, MAPE weight=5.6%, MTR: MAPE height=2.2%, MAPE weight=7.5%) CONCLUSION: This study has demonstrated that the estimation of the patient's height and weight by a DL-based 3D camera algorithm is accurate and robust. It has the potential to complement the regular MRI workflows, by providing further automation during patient registration.

12.
Clin Neuroradiol ; 34(1): 75-83, 2024 Mar.
Article En | MEDLINE | ID: mdl-37589739

PURPOSE: Nonenhanced computed tomography (CT) of the head is among the most commonly performed CT examinations. The spectral information acquired by photon counting CT (PCCT) allows generation of virtual monoenergetic images (VMI). At the same time, image noise can be reduced using quantum iterative reconstruction (QIR). In this study, the image quality of VMI was evaluated depending on the keV level and the QIR level. Furthermore, the influence of the cranial calvaria was investigated to determine the optimal reconstruction for clinical application. METHODS: A total of 51 PCCT (NAEOTOM Alpha, Siemens Healthineers, Erlangen, Germany) of the head were retrospectively analyzed. In a quantitative analysis, gray and white matter ROIs were evaluated in different brain areas at all available keV levels and QIR levels with respect to signal, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). The distance to the cranial calvaria of the ROIs was included in the analysis. This was followed by a qualitative reading by five radiologists including experienced neuroradiologists. RESULTS: In most ROIs, signal and noise varied significantly between keV levels (p < 0.0001). The CNR had a focal maximum at 66 keV and an absolute maximum at higher keV, slightly differently located depending on ROI and QIR level. With increasing QIR level, a significant reduction in noise was achieved (p < 0.0001) except just beneath the cranial calvaria. The cranial calvaria had a strong effect on the signal (p < 0.0001) but not on gray and white matter noise. In the qualitative reading, the 60 keV VMI was rated best. CONCLUSION: In nonenhanced PCCT of the head the selected keV level of the VMI and the QIR level have a crucial influence on image quality in VMI. The 60 keV and 66 keV VMI with high QIR level provided optimal subjective and objective image quality for clinical use. The cranial calvaria has a significant influence on the visualization of the adjacent brain matter; currently, this substantially limits the use of low keV VMIs (< 60 keV).


Radiography, Dual-Energy Scanned Projection , Humans , Retrospective Studies , Radiography, Dual-Energy Scanned Projection/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Skull/diagnostic imaging
13.
Acad Radiol ; 31(2): 686-692, 2024 Feb.
Article En | MEDLINE | ID: mdl-37393176

RATIONALE AND OBJECTIVES: To evaluate the potential to reduce the amount of iodinated contrast media (CM) for computer tomographic pulmonary angiography (CTPA) with a novel photon-counting-detector CT (PCCT). MATERIALS AND METHODS: Overall, 105 patients referred for CTPA were retrospectively included in this study. CTPA was performed using bolus tracking and high-pitch dual-source scanning (FLASH mode) on a novel PCCT (Naeotom Alpha, Siemens Healthineers). CM (Accupaque 300, GE Healthcare) dose was lowered stepwise following the introduction of the new CT scanner. Thus, patients could be divided into 3 groups as follows: group 1, n = 29, 35 ml of CM; group 2, n = 62, 45 ml of CM and group 3, n = 14, 60 ml of CM. Four readers independently assessed the image quality (Likert-scale 1-5) and adequate assessment of the segmental pulmonary arteries. Additionally, the pulmonary arterial contrast opacification was measured. RESULTS: The subjective image quality was rated highest in group 1 with 4.6 compared to 4.5 (group 2) and 4.1 (group 3) with a significant difference between groups 1 and 3 (p < 0.001) and between groups 2 and 3 (p = 0.003). In all groups, almost all segmental pulmonary arteries could be assessed adequately without significant differences (18.5 vs. 18.7 vs. 18.4). Mean attenuation in the pulmonary trunk did not differ significantly between groups 321 ± 92 HU versus 345 ± 93 HU versus 347 ± 88 HU (p = 0.69). CONCLUSION: Significant CM dose reduction is possible without a reduction in image quality. PCCT enables diagnostic CTPA with 35 ml of CM.


Contrast Media , Pulmonary Embolism , Humans , Pulmonary Embolism/diagnostic imaging , Retrospective Studies , Pulmonary Artery/diagnostic imaging , Tomography, X-Ray Computed/methods , Angiography/methods , Computed Tomography Angiography/methods , Radiation Dosage
14.
World Neurosurg ; 182: e517-e524, 2024 Feb.
Article En | MEDLINE | ID: mdl-38043742

OBJECTIVE: In preliminary studies, advanced intracranial stents appear to have a favorable safety profile for intracranial aneurysm treatment. This dual-center study is a head-to-head comparison of the low-profile Acandis Acclino stent (a third-generation stent) and the first- and second-generation Enterprise stent. METHODS: Patients who underwent stent-assisted coiling with either the Enterprise or the Acclino stent for unruptured aneurysms during an 8-year period were enrolled and compared for complications, clinical outcomes, and angiographic results. Primary outcome measures were ischemic stroke rate and mid-term complete occlusion rate. Propensity score adjustment was performed to account for small differences between the groups. RESULTS: Enterprise and Acclino stents were used in 48 cases each. The overall rate of thrombotic complications was higher in the Enterprise group than in the Acclino group (20.8% vs. 4.2%, HR: 6.6, 95%CI: 2.2-20.0, P = 0.01, adjusted P < 0.01), which translated into a higher rate of major ischemic stroke after Enterprise treatment (6.3% vs. 0%, HR: 2.1, 95%CI: 1.8-2.4, P = 0.08, adjusted P < 0.01). Mid-term and long-term angiographic follow-up showed complete occlusion rates of 83.3% and 75.0% for Enterprise and 89.2% and 75.9% for Acclino (both P > 0.05). Retreatment rates were 10.4% in the Enterprise group and 4.2% in the Acclino group (P = 0.42, adjusted P = 0.10). CONCLUSIONS: The results indicate a favorable safety profile of the Acclino over the Enterprise, justifying the use of advanced stent systems in clinical practice. However, further comparative studies of the Acclino and other competing stent systems are needed to draw a definitive conclusion on the state of stent-assisted coiling.


Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Ischemic Stroke , Humans , Treatment Outcome , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/surgery , Retrospective Studies , Endovascular Procedures/methods , Stents , Embolization, Therapeutic/methods , Cerebral Angiography , Ischemic Stroke/therapy
15.
Acad Radiol ; 31(5): 1784-1791, 2024 May.
Article En | MEDLINE | ID: mdl-38155024

RATIONALE AND OBJECTIVES: The prognostic role of pericardial effusion (PE) in Covid 19 is unclear. The aim of the present study was to estimate the prognostic role of PE in patients with Covid 19 in a large multicentre setting. MATERIALS AND METHODS: This retrospective study is a part of the German multicenter project RACOON (Radiological Cooperative Network of the Covid 19 pandemic). The acquired sample comprises 1197 patients, 363 (30.3%) women and 834 (69.7%) men. In every case, chest computed tomography was analyzed for PE. Data about 30-day mortality, need for mechanical ventilation and need for intensive care unit (ICU) admission were collected. Data were evaluated by means of descriptive statistics. Group differences were calculated with Mann-Whitney test and Fisher exact test. Uni-and multivariable regression analyses were performed. RESULTS: Overall, 46.4% of the patients were admitted to ICU, mechanical lung ventilation was performed in 26.6% and 30-day mortality was 24%. PE was identified in 159 patients (13.3%). The presence of PE was associated with 30-day mortality: HR= 1.54, CI 95% (1.05; 2.23), p = 0.02 (univariable analysis), and HR= 1.60, CI 95% (1.03; 2.48), p = 0.03 (multivariable analysis). Furthermore, density of PE was associated with the need for intubation (OR=1.02, CI 95% (1.003; 1.05), p = 0.03) and the need for ICU admission (OR=1.03, CI 95% (1.005; 1.05), p = 0.01) in univariable regression analysis. The presence of PE was associated with 30-day mortality in male patients, HR= 1.56, CI 95%(1.01-2.43), p = 0.04 (multivariable analysis). In female patients, none of PE values predicted clinical outcomes. CONCLUSION: The prevalence of PE in Covid 19 is 13.3%. PE is an independent predictor of 30-day mortality in male patients with Covid 19. In female patients, PE plays no predictive role.


COVID-19 , Pericardial Effusion , Tomography, X-Ray Computed , Humans , Male , Female , COVID-19/mortality , COVID-19/epidemiology , COVID-19/diagnostic imaging , COVID-19/complications , Retrospective Studies , Pericardial Effusion/diagnostic imaging , Pericardial Effusion/epidemiology , Aged , Middle Aged , Prognosis , Germany/epidemiology , Respiration, Artificial/statistics & numerical data , SARS-CoV-2 , Intensive Care Units , Aged, 80 and over
16.
In Vivo ; 38(1): 281-285, 2024.
Article En | MEDLINE | ID: mdl-38148083

BACKGROUND/AIM: Epicardial adipose tissue (EAT) has been established as a quantitative imaging biomarker associated with the prognosis of several diseases, especially cardiovascular diseases. The cardiac injury by coronavirus disease 2019 (COVID-19) might be linked to the EAT. This study aimed to use this prognostic marker derived from computed tomography (CT) images to predict 30-day mortality in patients with COVID-19. PATIENTS AND METHODS: Consecutive patients with COVID-19 were retrospectively screened between 2020 and 2022. Overall, 237 patients (78 female, 32.9%) were included in the present study. The study end-point was the 30-day mortality. EAT was measured using the diagnostic CT in a semiquantitative manner. EAT volume and density were measured for each patient. RESULTS: Overall, 70 patients (29.5%) died within the 30-day observation period and 143 patients (60.3%) were admitted to the intensive care unit (ICU). The mean EAT volume was 140.9±89.1 cm3 in survivors and 132.9±77.7 cm3 in non-survivors, p=0.66. The mean EAT density was -71.9±8.1 Hounsfield units (HU) in survivors, and -67.3±8.4 HU in non-survivors, p=0.0001. EAT density was associated with 30-day mortality (p<0.0001) and ICU admission (p<0.0001). EAT volume was not associated with mortality and/or ICU admission. CONCLUSION: EAT density was associated with 30-day mortality and ICU admission in patients with COVID-19.


COVID-19 , Coronary Artery Disease , Humans , Female , Epicardial Adipose Tissue , Prognosis , Retrospective Studies , Adipose Tissue/diagnostic imaging
17.
Rofo ; 2023 Dec 22.
Article En, De | MEDLINE | ID: mdl-38134902

BACKGROUND: Sarcopenia is defined as a loss of muscle mass and strength as well as decreased physical performance. METHOD: The present study provides a systematic overview of the current literature in regard to the prognostic role of sarcopenia in oncology. CONCLUSION: In oncologic patients, sarcopenia occurs in 39.6 % of cases in a curative setting and in 49.2 % in a palliative setting. Sarcopenia is associated with dose-limiting toxicity. Furthermore, sarcopenia is associated with the occurrence of postoperative complications. Also, reduced muscle mass limits overall survival in most tumors both in a curative and a palliative setting. Therefore, analysis of the skeletal musculature on staging CT should be implemented in the clinical routine in oncology. KEY POINTS: · In oncologic patients, the prevalence of sarcopenia is 39.6 % in a curative setting and 49.2 % in a palliative setting.. · Sarcopenia is associated with dose-limiting toxicity and treatment response.. · Sarcopenia predicts overall survival in oncologic patients.. CITATION FORMAT: · Surov A, Wienke A, Gutzmer R et al. Prognostic role of the skeletal musculature in oncology: significance, coherences and clinical implications. Fortschr Röntgenstr 2023; DOI: 10.1055/a-2213-2320.

18.
Medicine (Baltimore) ; 102(47): e36069, 2023 Nov 24.
Article En | MEDLINE | ID: mdl-38013308

The purpose of the present study was to evaluate the subjectively perceived patient comfort during magnetic resonance imaging (MRI) examinations and to assess potential differences between a recently introduced low field MRI scanner and a standard MRI scanner. Among other characteristics, the low field MRI scanner differs from the standard MRI scanner by offering more space (wider bore size of 80 centimeter diameter) and producing less noise, which may influence the patient comfort. In total, 177 patients were surveyed after MRI scans with either the low field MRI scanner (n = 91, MAGNETOM Free.Max, Siemens Healthineers) or the standard MRI scanner (n = 86, MAGNETOM Avanto Fit, Siemens Healthineers). Patients rated different aspects of comfort on a 5 point Likert scale: (a) claustrophobia, (b) comfort of the scanner table, (c) noise level and (d) vertigo during the scanning procedure. In terms of claustrophobia and comfort of the scanner table, patients rated both MRI scanners similar (e.g., mean ratings for claustrophobia: standard MRI scanner = 4.63 ± 1.04, low field MRI scanner = 4.65 ± 1.02). However, when asked for a comparison, patients did favor the more spacious low field MRI scanner. In terms of noise level, the low field MRI scanner was rated significantly better (mean ratings: standard MRI scanner = 3.72 ± 1.46 [median 4 = "rather not unpleasant"], low field MRI scanner = 4.26 ± 1.22 [median 5 = "not unpleasant at all"]). Patients did not perceive any significant difference in terms of vertigo between both MRI scanners. The newly developed low field MRI scanner offers constructional differences compared to standard MRI scanners that are perceived positively by patients. Worth highlighting is the significantly lower noise level and the innovative bore diameter of 80 centimeter, which offers more space to the patients.


Patient Comfort , Phobic Disorders , Humans , Magnetic Resonance Imaging/adverse effects , Magnetic Resonance Imaging/methods , Vertigo/diagnostic imaging , Perception
19.
J Thorac Dis ; 15(10): 5559-5565, 2023 Oct 31.
Article En | MEDLINE | ID: mdl-37969270

Background: Coronary artery calcification (CA) score has been established as a quantitative imaging biomarker to reflect arteriosclerosis and general vessel status. It is established as an important prognostic factor for coronary heart disease but also for other disease entities. Our aim was to use this imaging marker derived from computed tomography (CT) images to elucidate the prognostic relevance in patients with coronavirus disease 2019 (COVID-19). Methods: The clinical database was retrospectively screened for patients with COVID-19 between 2020 and 2022. A total of 241 patients (85 female patients, 35.3%) were included into the analysis. CA scoring was performed semiquantitatively on thoracic CT images with the established Weston score. Results: Overall, 61 patients (25.3%) of the investigated patient sample died. In survivors, the mean CA score was 2.3±3.0 and in non-survivors, it was 4.2±4.1 (P=0.002). In univariable regression analysis, CA was associated with 30-day mortality [odds ratio (OR) =1.15; 95% confidence interval (CI): 1.06-1.25, P<0.001]. These results were confirmed by the multivariable regression analysis adjusted for age and sex, the CA score predicted 30-day mortality (OR =1.28; 95% CI: 1.08-1.4, P=0.002). Conclusions: CA score is an independent risk factor in COVID-19. As CA scoring can easily be performed by the radiologist, it should be further investigated as an imaging marker in patients with COVID-19 and potentially be translated into clinical routine.

20.
J Stroke Cerebrovasc Dis ; 32(12): 107421, 2023 Dec.
Article En | MEDLINE | ID: mdl-37826941

BACKGROUND: Sarcopenia is proposed as a novel imaging biomarker in several acute conditions regarding outcome and mortality. The aim of the present study was to investigate the prognostic role of the masseter muscles in patients with acute ischemic stroke (AIS). METHODS: Overall, 189 patients with AIS that received mechanical thrombectomy were retrospectively enrolled in this study. Outcome and overall survival after 90 days were analyzed. Transversal surface area and density of the masseter muscles were measured. The diagnostic performance for the estimation of a) favorable modified ranking scale 90 days (mRS 90) outcome and b) death at 90 days was calculated using univariate and multivariate logistic regression analysis, followed by receiver operating characteristics and Odds ratios. RESULTS: The masseter muscle area provided a significant difference between patients who survived and those who died and between patients who had a favorable outcome (mRS 90 < 3) and those who did not. The cutoff for a favorable mRS 90 was found to be 435.8 mm2 for men and 338.8 mm2 for women, the cutoff for the prediction of death 421.3 mm2 for men and 326.6 mm2 for women. Masseter muscle area was the third strongest predictor in both categories after patient age and NIHSS. CONCLUSIONS: Masseter muscle area is an independent predictor of mortality in patients with AIS.


Brain Ischemia , Ischemic Stroke , Sarcopenia , Stroke , Male , Humans , Female , Stroke/diagnostic imaging , Stroke/therapy , Brain Ischemia/diagnostic imaging , Brain Ischemia/therapy , Treatment Outcome , Retrospective Studies , Sarcopenia/diagnostic imaging , Risk Factors , Thrombectomy/methods
...